Hazardous Material
Acetaldehyde
HSE Sampling Methods MDHS
MDHS 70
Method Number
N10SH 3507 3
Hazard Type
Highly Flammable
8 Hour
WEL ppm
8 Hour
WEL mg/m3
STEL
WEL ppm
STEL
WEL mg/m3
20
37
50
92
Air Flow Rate L/min
0.1
Sample Analysis
High Performance Liquid Chromatography+ UV spectrophotometer
Direct Reading Method (if available)
Voc Pro
Pump and Extras Required
Apex
Head Type Code
-
Media
-
Casella Kit No.
Part No.
Qty
1
P104126
PLUS
Additional Accessories Required
Liquid sampler with carbon trap
Part Numbers
P100011 P109018
Contact Casella sales office
for further information
Please add the quantities you
require and click here
This Kit Finder should be used for reference only. Please refer to the latest relevant legislation before undertaking any air sampling survey.
More in-depth reference is available in the UK from
www.hse.gov.uk
To order immediately or for further information please call our sales team on 01234 841468